Main content

Simplified Model for the Design of an Oscillometric Blood Pressure Measuring System

Show simple item record

dc.contributor.advisor Gregori, Stefano
dc.contributor.advisor Fayek, Dalia
dc.contributor.author James, Matthew
dc.date.accessioned 2013-01-14T16:09:25Z
dc.date.available 2013-01-14T16:09:25Z
dc.date.copyright 2012-06
dc.date.created 2012-12-07
dc.date.issued 2013-01-14
dc.identifier.uri http://hdl.handle.net/10214/5316
dc.description.abstract The oscillometric method for blood pressure measurement has been known for over a century. It was overshadowed by the classic stethoscope and cuff method until more recently when its ease of automation became useful. It is now found in the automated blood pressure cuffs used in hospitals, doctor's offices, pharmacies, and devices sold for home use. It still challenges accurate blood pressure measurement, however, due to its difficulty in compensating for pregnancy, age, hypo-, and hypertension. Global sensitivity analysis methods were used to develop a model that focuses on the most important system parameters. The most influential biological and design parameters were identified allowing the removal or fixing of less influential parameters, and the replacement of subsystems with linear models, with minimal effect on the overall system accuracy. The developed model allows for the investigation and development of new methods for extracting parameter information from the oscillometric signals. This is illustrated by the development of a method to extract the artery's cross-sectional area from standard oscillometric output. The system design requirements for accurate measurement of blood pressure are examined and discussed with recommendations for system parameter adjustment. The model's performance and usefulness is highlighted with modelled case studies of potential real-world applications for subjects with parameters or inputs for which the oscillometric method would find it difficult to compensate. Through the use of the developed model to compensate for the system errors, the measurement error can be reduced by half. Highlighting the important system parameters allows the engineer to focus on choosing the design parameters over which she or he has control. The system model provides the ability to experiment with the cuff design choices and provides information regarding system performance under conditions that are historically difficult to measure accurately. The developed model's usefulness is illustrated by applying it to parameter extraction, and to the compensation of oscillometric blood pressure readings. en_US
dc.language.iso en en_US
dc.subject oscillometric en_US
dc.subject blood pressure en_US
dc.subject system modelling en_US
dc.subject cuff en_US
dc.title Simplified Model for the Design of an Oscillometric Blood Pressure Measuring System en_US
dc.type Thesis en_US
dc.degree.programme Engineering en_US
dc.degree.name Doctor of Philosophy en_US
dc.degree.department School of Engineering en_US
dc.rights.license All items in the Atrium are protected by copyright with all rights reserved unless otherwise indicated.


Files in this item

Files Size Format View
James_Matthew_20130114_Phd.pdf 2.173Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record